ZW-LXZ series <strong> steel double rotor flowmeter</strong> is currently the ideal gene…
Description:
Productoverview:
ZW-LXZ series steel double rotor flowmeter is currently the ideal generation volume flowmeter.Is a kind of unique design, a new kind of flowmeter precision machining and assembly.A pair of spiral rotor body * metering cavity movement to segmentation, measurement, transportation and excretion of the fluid to be measured.This type of flowmeter increases the gear position in the structure, the two rotor in rotation to each other without contact.The flowmeter work smooth operation and low noise, little abrasion, high accuracy, viscosity adaptability, can allow the measured fine particles in the liquid through which is not easy to watch.
Two, structure principle:
1, principle:
ZW-LXZ series steel double rotor flowmeter for fluid flow measurement is completed in the measurement of cavity.A pair of spiral rotor rotating in the liquid under the pressure of a closed space is formed between the rotor and the measurement of cavity wall (Figure shadow) of each swing time through 8 times the volume of the shadow.According to this relationship, as long as the measurement of rotating frequency, we can calculate the flow accumulation, according to the second revolution, it can be used to measure the instantaneous flow.
2, structure:
Double rotor flowmeter is mainly composed of a casing, a pair of spiral rotor, magnetic coupling, reducer, gear adjustment, counter and signaling device. The body is divided into flowmeter monomer and dimer monomer is two. The shell and the box flowmeter as a whole; the shell and the two meter catamaran. The spiral rotor speed reducer. The mechanism of magnetic coupling and a series of gears, to meter counter. The magnetic coupling is mainly composed of a driving magnet and the driven magnetic steel. The magnetic coupling flowmeter can improve the working pressure and temperature, safe operation, convenient maintenance.
Third, application:
ZW-LXZ series steel double rotor flowmeter is used in pipeline liquid flow measurement and control instrument.Widely used in petroleum, chemical, metallurgy, electric power, transportation, shipbuilding, oil depots, docks, tankers and other departments, especially for the measurement of crude oil, refined oil, flowmeter in light hydrocarbon and other industrial liquids can be directly read the instructions, word and dispensing hearing, output electric pulse signal transmitted to the secondary instrument or computer composition, automatic control, automatic detection and data processing system.
Fourth, the main features:
1, high accuracy, good repeatability, stable operation, no pulsation and long service life;
For straight section 2, flow meter and no small installation space;
3, the flow is not affected by the accuracy of impact pressure and flow changes, stable performance;
4, with the temperature and pressure sensor, the gas temperature and pressure compensation;
5, with the pulse signal, analog signal, and can realize the centralized management of computer real-time data through the RS485 communication interface;
6, low power consumption, by battery power supply, also can be an external power supply;
7, special high resolution liquid crystal display, intuitive and convenient reading.
Fifth, technical parameters:
1, can be measured in liquid petroleum, petroleum products, chemical medium etc.;
6, the temperature range (c) -20 ~ +60, -20 ~ +120, +100 ~ +200, +150 ~ +250;
7, protection grade IP65;
8, environmental temperature (-30 ~ +70 C);
9, medium viscosity (0.32 ~ 1000mPa.smPa.s);
Installation requirements:
1, environmental conditions: no corrosive fluids, small mechanical vibration, less dust and place away from heat.For a volume correction instrument of intelligent flowmeter, should also comply with the provisions of the environment.
2, environmental temperature: not more than -20, the range of +8O DEG C.
3, the pipeline conditions: installation in front of flowmeter, piping must be cleaned and purged, remove all debris, rust and dirt.Connecting pipe should be in accordance with the import and export of the same caliber flowmeter axis, may not have bulges protruded convex wall in the pipeline.Flow meter should take the stress free installation, considering pipe work caused by temperature stress.
As a new type of flowmeter, only to meet the conditions and according to the requirements of the correct use, can make use of the ideal price, prolong the service life.Therefore must pay attention to the following 3 problems in the selection and use of.
1, because the single shell structure, Zui high pressure is higher than that of 2.0MPa, so is the use of high-pressure long pipeline transportation.
2, non consecutive occasions when used again, must from the exhaust hole net metering cavity air to prevent cavitation caused by measuring error increases and graphite bearing damage.
3, the rotor clearance is not higher than 0.2 m, and the medium in the metering chamber to travel longer, the medium purity requirements than other volumetric flowmeter, requiring the use of not less than 40 to the stainless steel filter and regular cleaning.The rotor is cast iron, medium water requirement rate is less than 5%, otherwise it will affect the use of corrosion.
Seven, installation notes:
1, the installation direction should be the direction of the arrow shown on the instrument shell and liquid flow in the same direction, the installation position should pay attention to reading
2, try to install instruments in normal occasions, do not install in harmful gases and strong thermal radiation situations, to prevent damage to the counter part of instrument.
The rotor shaft 3, the instrument as much as possible to install the horizontal position, the dial should be installed into the vertical position ("0" in the above indexing), to reduce the friction between the gear and the shell, reducing the wear of parts.Due to the different installation positions, in order to facilitate the reading, the counter (header) rotating 90 degrees or 180 degrees.Electronic meter installation with vertical installation, head of state and at right angles to the body, easy to read.
Before installation, 4 meters, the pipeline must be cleaned thoroughly in the piping system, if there is no strict filtering device, filters should be installed in the instrument, to prevent impurities from entering the table.
5, should be installed in the pump outlet, the flow control valve should be installed in the instrument downstream, when used to open the upstream valve, then slowly open the downstream flow regulating valve or.Is suddenly turned on or off.
6, in the use of instruments, should be full of liquid flow in the table.Tested in vivo should not be mixed with gas, mixed volume measurement not otherwise measured air and liquid.The liquid is mixed in the gas must be installed in the instrument before gettering.
7, the flow of the pipeline should not dramatically increase or decrease, should be avoided and pressure piping vibration, hydraulic shock volatility phenomenon, otherwise it will affect the normal work of instruments.
8 Z, the flow exceeds the specified flow is large, with double rotor speed of wear increases, and the pressure loss increased sharply, should avoid the use of less than Z, small flow, still can measure, but the error increases, the starting flow flowmeter is about Zui high flow 3%, normal work flow for the Z flow of 70%-80%.
9, for the measurement of high viscosity liquid, generally the liquid is heated to reduce viscosity, and flow in the pipe, when the instrument is disabled, liquid cooling instrument filled with the variable viscosity, such as to enable, must use steam or thermal oil in the body, the external heating liquid red hot method for liquid viscosity the instrument can be used after reduced.Otherwise the viscosity will bite the transmission parts, resulting in damage to the instrument.
The additional error can also cause changes in the temperature of the liquid viscosity influence.In addition, the temperature also caused an increase in spiral space volume increased, the instrument "go slow",
The factory 11, each meter, with diesel at room temperature under normal temperature calibration, oil density: 0.84M3/KG, such as liquid viscosity users and this difference is larger, can exchange the double gear or adjust the instrument coefficient to correct the error.
12, prohibit the use of purging steam and water through the instrument.
Eighth, structure and dimensions:
1, rotor structure
Rotor assembly
2, the overall structure of intelligent meter
The overall structure of intelligent meter:
Note: 1, 2., 3. and two times the battery meter table 4. connecting seat type 5.U 6. - 7. cap positioning 9.O type ring gear 8. on the cover 10. 11. 12. 13. of the main rotor shaft, the upper cover 14. thrust bearing 15. adjustment screws 16. bottom cover 17. remote.
See Table 3, size:
entry name
Nominal pressureMpa
Size
Flange size
Bolt
L
D
H
H1
D1
D2
D3
X
Y
H
T
T1
Number
Thread
ZW-LXZ80
1.6, 2.5
Three hundred and eighty
Two hundred and seventy
Six hundred and ninety
One hundred and fifty-four
One hundred and ninety-five
One hundred and sixty
One hundred and thirty-five
Twenty
Three
Eight
Ml6
4, 6.4
Three hundred and eighty
Two hundred and seventy
Six hundred and ninety
One hundred and fifty-four
Two hundred and twenty
One hundred and seventy-two
One hundred and forty
One hundred and twenty-seven
One hundred and twenty-eight point six
Thirty
Seven
Five
Eight
M20
10, 16
ZW-LXZ100
Three hundred and eighty
Three hundred and fifty-two
Seven hundred and forty
One hundred and ninety
Two hundred and thirty
One hundred and ninety
One hundred and sixty
Twenty-two
Three
Eight
M20
4, 6.4
Three hundred and eighty
Three hundred and fifty-two
Seven hundred and forty
One hundred and ninety
Two hundred and sixty
Two hundred and four
One hundred and seventy
One hundred and fifty-seven
One hundred and fifty-eight point eight
Thirty-two
Seven
Five
S
M22
10, 16
ZW-LXZ150
1.6, 2.5
Five hundred and sixty
Four hundred and twenty
Eight hundred and forty
Two hundred and twenty
Three hundred
Two hundred and fifty
Two hundred and eighteen
Twenty-seven
Three
Eight
M20
4, 2.4
Five hundred and sixty
Four hundred and twenty
Eight hundred and forty
Two hundred and twenty
Three hundred and thirty
Two hundred and eighty
Two hundred and twenty-eight
Two hundred and sixteen
Two hundred and seventeen point five
Thirty-eight
Seven
Five
1 "'
M24
10, 16
ZW-LXZ200
1.6, 2.5
Seven hundred
Five hundred and sixty
Eight hundred and ninety
Two hundred and forty
Three hundred and sixty
Three hundred and ten
Two hundred and seventy-four
Twenty-seven
Three
Twelve
M24
4, 6.4
Seven hundred
Five hundred and sixty
Eight hundred and ninety
Two hundred and forty
Three hundred and seventy-five
Three hundred and twenty
Two hundred and eighty-four
Two hundred and fifty-seven point five
Two hundred and fifty-nine
Thirty-four
Seven
Five
Twelve
M28
10, 16
ZW-LXZ250
1.6, 2.5
One thousand
Seven hundred and twenty
1100
Two hundred and seventy
Four hundred and twenty-five
Three hundred and seventy
Three hundred and thirty
Twenty-nine
Three
1 "'
M24
4, 6.4
One thousand
Seven hundred and twenty
One thousand and one hundred
Two hundred and seventy
Four hundred and forty-five
Three hundred and thirty-eight
Three hundred and thirty-five
Three hundred and twenty-four
Three hundred and twenty-five point five
Forty-eight
Seven
Five
Sixteen
M28
10, 16
ZW-LXZ300
<, >1.6,Two point five 1.6, 2.5
One thousand
Seven hundred and twenty
One thousand two hundred and thirty
Four hundred
Four hundred and eighty-five
Four hundred and thirty
Three hundred and ninety
Thirty
Four
1.
M24
4, 6.4
One thousand
Seven hundred and twenty
One thousand two hundred and thirty
Four hundred
Five hundred and twenty
Four hundred and fifty-one
Three hundred and ninety-two
Three hundred and eighty-one
Three hundred and twenty-eight point six
Fifty-one
Seven
Five
Sixteen
M30
Nine, measuring range:
LXZ-80
Eighty
9~36
4.5~36
3.6~36
3.6~36
2.8~25
2.8~25
4.5~18
LXZ-80
20~80
10~80
10~100
10~100
6.5~56
6.5~56
5~40
LXZ-100
One hundred
20~80
10~80
10~100
10~100
6.5~56
6.5~56
5~40
LXZ-100
25~100
13~100
15~150
15~150
8.5~80
8.5~80
6.5~55
LXZ-150
One hundred and fifty
25~100
13~100
15~150
15~150
8.5~80
8.5~80
6.5~55
LXZ-150
55~225
30`250
25~250
25~250
18~150
18~150
10~100
LXZ-200
Two hundred
55~225
30`250
25~250
25~250
18~150
18~150
10~100
LXZ-200
90~360
50~400
40~400
40~400
28~240
28~240
20~160
LXZ-250
Two hundred and fifty
90~360
50~400
40~400
40~400
28~240
28~240
20~160
LXZ-250
130~540
65~540
60~600
60~600
42~360
42~360
30~240
LXZ-300
Three hundred
130~540
65~540
60~600
60~600
42~360
42~360
30~240
LXZ-300
220~800
110~900
95~950
95~950
70~600
70~600
54~450
LXZ-350
Three hundred and fifty
220~800
110~900
95~950
95~950
70~600
70~600
54~450
Ten, the selection of encoding:
The basic model
One
Two
Three
Four
Five
Six
Description (Zhongwei control)
Nominal diameter
Counter
Nominal pressure
Features
Transmitter
working temperature
ZW-LXZ-E
Said: double rotor flowmeter
Eight
The nominal diameter of 8mm
Three hundred and fifty
The nominal diameter of 350mm
W
No message header pulse
J
Mechanical counter
E
Electronic counter
H
Zero mechanical counter
One point six
The nominal pressure is 1.6Mpa
Two point five
The nominal pressure of 2.5 Mpa
Four
The nominal pressure of 4 Mpa
Six point three
The nominal pressure of 6.3 Mpa
Three hundred and four
The rotor is 304 stainless steel
Three hundred and sixteen
The rotor is 316 stainless steel
C304
Shell, rotor for 304 stainless steel
C316
Shell, rotor for 316 stainless steel
F
Pulse output
I
4-20 mA output current.
A
Working temperature -20~+80
B
Working temperature -20~+150
C
Working temperature -20~+250
D
Working temperature -20~+350
Eleven, design selection and ordering instructions:
1, the name and type of flowmeter.Specification and material etc..
2, medium temperature (c) and pressure (Mpa), flow range (m3/h).
3, medium viscosity or medium name.
4, there are no special requirements (such as explosion-proof etc.).
5, you need a detailed understanding of the product, please call for information.
6, you need to display instrument Zhongwei control, please refer to the corresponding instructions, the appropriate choice of models or provided by the technical personnel of our company according to your information for your selection.
Customer service service commitment:
1, my company sold Zhongwei double rotor flowmeter series product quality problems within twelve months, responsible for free maintenance.
2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.