Bearing load detection cable

承荷探測(cè)電纜.jpg
  • 承荷探測(cè)電纜.jpg
Bearing load detection cable is suitable for electrical measurements of mechanical load under oil de…

Description:

One, the cable's brief introduction:
Bearing load detection cable is suitable for electrical measurements of mechanical load under oil detection cable, this type of cable is used for all kinds of oil and gas well logging, perforation and coring operation;Can also be used in ocean, river, harbor, water conservancy, hydrographic survey, coalfield geological prospecting, geothermal well logging, etc.As weighing measuring instrument connections.
Second, the production standards
JB3302-1999 
Three, bearing load detection cable model name:

model
The name says
W7X
7 core natural styrene-butadiene rubber insulation double steel wire armoured bearing load detection cable
W7F46
7 core fep insulated double steel wire armoured bearing load detection cable
W7F46P
7 core fep insulated total shielding double steel wire armoured bearing load detection cable
W7F46PP
7 core fep insulated split-phase total shield the double steel wire armoured bearing load detection cable

Three, bearing load cable detection use performance:
1) cable allows the use of temperature range

Type no.
Using temperature range (℃)

No less than

Short-term stay for no more than 2 hours (a) above

W7X
- 40
90
W7F46
- 50
232
W7F46P
- 50
232
W7F46PP
- 50
232

(2) the winch drum diameter should not less than 400 mm, wellhead pulley, day pulley, the pulley of the bending radius should not less than 230 mm, pulley groove should be in line with the cable diameter
(3) the some of the cable length, cross section, tensile force, nominal rating manufacturing

Type no.
core
The number
Calculate the cross section
(mm2)
Nominal tensile
Power (KN)
Nominal manufacturing length (m)
W7X
7
0.56
44
-
-
-
-
-
3500
2200
W7F46
7
0.56
69
8000
7500
6500
5500
4200
3500
2200
W7F46P
7
0.56
69
8000
7500
6500
5500
4200
3500
2200
W7F46PP
7
0.56
69
8000
7500
6500
5500
4200
3500
2200

(4) the cable core dc resistance is not less than 36 Ω/km;Line between core, line between the core and armoured withstand ac 50 hz, 1000 v not breakdown voltage test for 1 minute