ZW-LZB/ (B Series) Stainless steel glass tube rotameter With the scale and the transparent glass tub…
Description:
Productoverview:
ZW-LZB/ (B Series)Stainless steel glass tube rotameterWith the scale and the transparent glass tube, can directly observe the instruction type flowmeter measured medium flow state.Suitable for measuring single-phase non pulsating fluid flow of liquid.From the measured parts in contact with the medium (except glass tubes) were produced by 0Cr18Ni9 or 0Cr17Ni12Mo2 materials, strong corrosion resistance, acid and alkali, can detect liquid oxidants and other corrosive flow.
Second, working principle:
(ZW-LZB/) B series stainless steel glass tube rotameter measuring part is made up of vertically mounted plough and cone glass tube in the tube can be moved up and down a floater.When has a certain kinetic energy measured medium flows through tubes of glass cone plough, the measured medium buoyancy will have the geometry of the float float, float flow line reading position corresponding to the plow cone on a glass tube I want to cooperate, can read this time through the instantaneous flow of fluid in a pipeline, with the change of fluid kinetic energy. The float position, are constantly changing, but also changes in the value of the corresponding read.
Third, application:
(ZW-LZB/) B series stainless steel glass tube rotameter is widely used in chemical, petroleum, light industry, medicine, food and environmental protection, measurement, scientific research departments, measuring single-phase non pulsating fluid (liquid or gas) flow.
Fourth, the main features:
1, small pressure loss.In the process of using, can be fully utilized, without a lot of effort too much, all the pressure can be fully used, there will be no loss.
2, reliable performance.In operation, frequent failure will not ensure good operation.When people are in the process of using, don't worry about running for it.Good performance, high reliability, can be assured use.
3, simple structure, convenient installation and use.The structure of the glass rotameter is simple, the installation is very convenient, can be installed in a short period of time.
4, cheap.Buy glass rotameter is cheap, has a great price advantage.
Five, technical parameters:
1, size: DN2 ~ 100mm;
2, measuring range: water (20 C): 1L/h ~ 100m3/h, gas (101325Pa, 20 C): 16L/h ~ 3000m3/h;
6, working temperature: less than or equal to 120 DEG c;
7, connection: hose, metal pipe, flange (GB/T9119-2000);
8, material: flange, float, a guide rod, a supporting plate and bolts are made of stainless steel 304 (1Cr18Ni9Ti), type LZB-B.
Wetted materials for the 316, is the model for the LZB-Bo, can be customized.
For stainless steel PTFE is type LZB-BF (or BoF), can be customized.
Six, installation instructions:
How to choose the right glass rotor flowmeter glass rotor flowmeter is instantaneous flow measurement instrument using a simple and convenient reading, a very wide range of uses.In the field of environmental protection equipment in the amount of up to instrument 30000 Taiwan / year.Therefore, choose and use this instrument is very important.
1, variety and selection
Glass rotor flowmeter according to its purpose and scope can be divided into: ordinary type, ribbed vascular type, small flow and low profile type, corrosion type, laboratory type, insulation type, alarm type and high pressure type eight series.According to the formulation of national instrument series, regardless of which Zui series, ranging from 1 to 100 mm in diameter and a total of 12 numbers, can measure the flow range: liquid (water) 0.1 ml / min to 40 cubic meters / hour, gas (air) 1 ml / min to 1000 cubic meters / hour.For environmental protection equipment of the glass rotameter is generally not more than 10 mm diameter, the flow measurement of small flow range.
2, correction
The scale of the glass rotameter, is a production plant with a nearly ideal fluid in the factory under the condition of water and dry air as the medium for the calibration.But in the meter the use of the site, there are two kinds of situations can not directly use its scale: one is not measuring medium of water and air, two is measured and the medium is water and air, but the condition (temperature. Pressure) is different from the scale of state.So, in the use of flow time, to get the correct measurement results, there need to revise the scale value problem.Therefore, to solve the glass rotameter scale correction, is the key to good use of this instrument.
Considering the environmental protection equipment used by mining gas rotameter medium flow in great quantities, so just below the gas medium when measuring the density correction is discussed.Because the gas medium viscosity is very small, so the effects of omitting discussion viscosity.Practice has proved that this does not affect the accuracy of the revised.
Seven, the selection of attention:
1, measurement.Measuring the media type, size, pressure and chemical properties.Such as liquid and gas medium, the corrosive medium should choose corrosion resistant glass rotor flowmeter.
2, the performance of flowmeter.The above conditions are identified in general, if the price is no big change, may be preferred needle valve is arranged on the upper part of the large circulation flow meter; hole, direct flow scale; simple structure; small exterior dimensions etc..Such as small flow range, you can choose to use the ball float type, because of its measurement stability, not easy dust, high precision, good interchangeability.
The price of 3, according to the.Generally speaking, the high price of high precision.According to the measurement instruments such as precision grade, only through the medium of control measure, the operation adjustment, after always stabilize the throughput, so the accuracy is minor.
4, the fluid flows through the cone bottom-up tube, buoyancy A fluid kinetic energy generated on the float lift S and fluid to float up, when the lift and buoyancy of A and S is equal to the gravity float G, float in the balance, stable at a certain height position, scale cone tube on the fluid flow indicator value.
Eight, specifications and measuring range:
1, ordinary type:
LZB-2
LZB-3
Model
LZB-4
LZB-6
LZB-10
Phi 2
Phi 3
Nominal diameter mm
Phi 4
Phi 6
Phi 10
Less than or equal to 1
Less than or equal to 1
The working pressure of MPa
Less than or equal to 1
Less than or equal to 1
Less than or equal to 1
+ 4
+ 4
Basic error limit%
+ 4
+ 2.5
+ 2.5
1:10
1:10
The scope of
1:10
1:10
1:10
0.4~4
2.5~25
liquid Ml/min
measuring range
liquid L/h
1~10
2.5~25
6~60
0.6~6
4~40
1.6~16
4~40
10~100
1~10
6~60
2.5~25
6~60
16~160
1.6~16
10~100
6~60
40~400
Gas Ml/min
Gas L/h
16~160
40~400
100~1000
10~100
60~600
16~160
100~1000
25~250
60~600
160~1600
25~250
160~1600
40~400
100~1000
250~2500
2, ordinary type:
Model
LZB-15
LZB-25
LZB-40
LZB-50
LZB-80
LZB-100
Nominal diameter
Phi 15
Phi 25
Phi 40
Phi 50
Phi 80
Phi 100
Ratio measurement
1:10
1:10
1:10
1:10
1:5 1:10
1:5
Working pressure
Less than or equal to 0.6
Less than or equal to 0.6
Less than or equal to 0.6
Less than or equal to 0.6
Less than or equal to 0.4
Less than or equal to 0.4
Precision grade
Two point five
One point five
One point five
One point five
One point five
One point five
Flow range
liquid
(m3/h)
16-160 (L/h)
40-400 (L/h)
0.16-1.6
0.4-4.0
1-10
5-25
25-250 (L/h)
60-600 (L/h)
0.25-2.5
0.6-6.0
1.6-16
8-40
40-400 (L/h)
100-1000 (L/h)
Gas
(NM3/h)
0.25-2.5
1-10
4-40
10-100
50-250
120-600
0.4-4.0
1.6-16
6-66
16-160
80-400
200-1000
0.6-6.0
2.5-25
3, corrosion resistance:
Model
LZB-15F
LZB-25F
LZB-40F
LZB-50F
LZB-80F
LZB-100F
Nominal diameter
Phi 15
Phi 25
Phi 40
Phi 50
Phi 80
Phi 100
Ratio measurement
1:10
1:10
1:10
1:10
1:5 1:10
1:5
Working pressure
Less than or equal to 0.6
Less than or equal to 0.6
Less than or equal to 0.6
Less than 0.4
Less than 0.4
Less than 0.4
Precision grade
Four
Two point five
Two point five
Two point five
Two point five
Two point five
Flow range
liquid
(m3/h)
16-160 (L/h)
40-400 (L/h)
0.16-1.6
0.4-4.0
1-10
5-25
25-250 (L/h)
60-600 (L/h)
0.25-2.5
0.6-6.0
1.6-16
8-40
40-400 (L/h)
100-1000 (L/h)
Gas
(NM3/h)
0.25-2.5
1-10
4.0-40
10-100
50-250
120-600
0.4-4.0
1.6-16
6.0-66
16-160
80-400
200-1000
0.6-6.0
2.5-25
4, LZB-S:
Model
LZB-15S
LZB-25S
LZB-50S
LZB-80S
Nominal diameter mm
Phi 15
Phi 25
Phi 50
Phi 80
The working pressure of MPa
Less than or equal to 0.6
Less than or equal to 0.6
Less than or equal to 0.6
Less than or equal to 0.4
The basic error indication limit%
+ 2.5
+ 2.5
+ 2.5
+ 2.5
measuring range
Liquid L/h
4~90
70~700
450~7000
7000~30000
Stainless steel
Flanges, a float, a guide rod, a supporting plate and bolts are made of stainless steel 304 (1Cr18Ni9Ti), type ZW-LZB- (B). Wetted materials such as the need to use 316, then type ZW-LZB- (Bo), can be customized. For stainless steel PTFE is type ZW-LZB- (BF) (or BoF), can be customized. PTFE type Base, float, needle with polytetrafluoroethylene (PTTFE).Support plate and screws made of stainless steel.
9, outline and installation dimensions:
Table 1,
Path
The size (mm)
A
B
C
D
E
Two
One hundred and ten
One hundred and thirty-two
One hundred and fifty
M8 * 1
31 x 26 (front)
Three
One hundred and ten
One hundred and thirty-two
One hundred and fifty
M8 * 1
31 x 26 (front)
Four
One hundred and seventy
Two hundred and eight
Two hundred and thirty-eight
Phi 11
40 x 34 (front)
Six
One hundred and seventy
Two hundred and eight
Two hundred and thirty-eight
Phi 11
40 x 34 (front)
Ten
One hundred and seventy
Two hundred and eight
Two hundred and thirty-eight
Phi 11
40 x 34 (front)
Table two:
Diameter (mm)
The size (mm)
A
B
C
D
E
Fifteen
Phi 95
Phi 65
Four hundred and seventy
Phi 15
With the diameter of 14 4-
Twenty-five
Phi 105
Phi 78
Four hundred and seventy
Phi 25
4- is 14
Forty
Phi 145
Phi 110
Five hundred and seventy
Phi 40
4- is 18
Fifty
Phi 160
Phi 125
Five hundred and seventy
Phi 50
With the diameter of 18 4-
Eighty
Phi 185
Phi 150
Six hundred and sixty
Phi 80
With the diameter of 18 4-
One hundred
Phi 205
Phi 170
Six hundred and sixty
Phi 100
With the diameter of 18 4-
10, encoding selection:
ZW-LZB
-
caliber
function
Description (Zhongwei control)
DN2-100
caliber
No label
Ordinary type
F
Corrosion proof type, PTFE base (for DN2~DN10) or carbon steel flange lining PTFE
B
All stainless steel material: 304 stainless steel
B0
All stainless steel material: 316 stainless steel
F/B (B0)
Type: stainless steel corrosion-resistant stainless steel flange (304 or 316) lined with PTFE (for DN15~DN100)
ZW-LZB
-
.
.
Zhongwei glass tube flowmeter
Note: the common type: mainly applicable to non corrosive medium measurement. Corrosion proof type: mainly suitable for corrosive medium measurement. All stainless steel type: mainly applicable to sanitary and weak corrosive medium measurement, can anti corrosive gas environment for use in Stainless steel corrosion proof type: mainly suitable for corrosive media measurement, can anti corrosive gas environment in use.
10, design and ordering:
1, please provide the pipe size, wall thickness, material requirements and accuracy requirements;
2, please provide the liquid or gas, such as the name, commonly used commonly used temperature, working pressure, common flow, density, viscosity etc.;
3, corrosion proof, should indicate the measured corrosion and concentration etc.;
4, if there are special to show, please with the Sales Department of the company.
Customer service service commitment:
1, our series of flowmeter series product quality problems occur in less than twelve months, is responsible for free repair.
2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
4, the warranty period after the product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.