国产精品视频久久久久久|亚洲精品视频网站在线观看视频|国产极品白嫩美女在线观看看|欧美一区和二区视频在线观看|国产美女在线观看精品网站免费

Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

Intelligent radar level gauge

6智能雷達(dá)液位計(jì)(防腐型)801.PNG
6智能雷達(dá)液位計(jì)(法蘭防腐型802.PNG
6智能雷達(dá)液位計(jì)(固定法蘭)803.png
6智能雷達(dá)液位計(jì)(喇叭口)804.png
6智能雷達(dá)液位計(jì)(高壓型)805.png
6智能雷達(dá)液位計(jì)(高溫型)806.png
  • 6智能雷達(dá)液位計(jì)(防腐型)801.PNG
  • 6智能雷達(dá)液位計(jì)(法蘭防腐型802.PNG
  • 6智能雷達(dá)液位計(jì)(固定法蘭)803.png
  • 6智能雷達(dá)液位計(jì)(喇叭口)804.png
  • 6智能雷達(dá)液位計(jì)(高壓型)805.png
  • 6智能雷達(dá)液位計(jì)(高溫型)806.png
Intelligent radar liquidometer extremely short of low transmission power microwave by transmitting a…

Description:

Products overview:

ZWRD800 seriesIntelligent radar level gaugeBy microwave pulse measurement method, and can be within the scope of industrial frequency band is normal, low beam energy, can be installed on a variety of metals, non-metallic, container or the pipe for liquid, paste, and granular material level for non-contact continuous measurement.Applicable to the dust, change of temperature, pressure, and presence of inert gas and steam.Radar level meter and environment are no harm to human body, but also has not influenced by the proportion of medium, not affected by dielectric constant change, do not need to live the advantages of school adjustment, both for industrial needs, or the consideration of economic material benefit to customers, is a good choice.

Second, the working principle:

ZWRD800 series intelligent radar liquid level gauge by microwave pulse measurement method, and can be within the scope of industrial frequency band is normal, low beam energy, can be installed on a variety of metals, non-metallic, container or the pipe for liquid, paste, and granular material level for non-contact continuous measurement.Applicable to the dust, change of temperature, pressure, and presence of inert gas and steam.No harm to human body and environment, let the customer buy intelligent radar level meter to buy the rest assured, worth to buy.High frequency microwave pulse by transmitting and receiving antenna system, radar wave running at the speed of light, running time can be transformed into material level signal by electronic parts.A special type of time extension method can guarantee the stability of a very short period of time and accurate measurement.Even if the condition is more complex cases, false echo, with a new micro processing technology and debug software can accurately identify the level of the echo.

The input

Antenna receiving the reflected microwave pulse and sending them to the electronic circuit, microprocessor to signal processing, identify the micro pulse produced by the echo in the material surface.Correct echo signal recognition completed by intelligence software, precision can reach millimeter level.Distance on the surface of the material distance D is proportional to the pulse of time travel T: D = C * T / 2

Where C is the speed of light

E known due to empty cans of distance, the level of L: L = E - D

The output

By entering empty cans height E (= zero), full tank height F (= full scale) and some applications to set parameters, application parameters will be automatically adapt instrument to measure the environment.Corresponding to the 4-20 ma output.

Applications:

ZWRD800 series intelligent radar level gauge is suitable for high temperature (350 ℃), high pressure, high vacuum, steam, dust and bad environment such as volatile gas.For continuous measurement of different materials.The instrument main technical indicators meet or exceed similar products at home and abroad, and convenient installation and debugging, can use a single, also can use network, can be widely used in metallurgy, building materials, energy, petrochemical, water conservancy, food and other industries.

Four, the application of medium:

Electricity plant, coal, raw coal, fuel storage, reservoir, exhaust gas purification tank, pump, ash library, tank, etc.;

Oil fields: crude oil or refined petroleum products storage tanks, three-phase separator, sedimentation tank, sewage tank, oil-water interface and drilling mud tank, etc.

Work: the crude distillation tower, raw material and intermediate bunker tank, reaction tank, ammonia, solid bin, separator, etc.;

Kim: smelting ore bin, ore mill, raw material warehouse, accessories warehouse, blast furnace, alumina powder storehouse, electrolytic cell buffer tank, etc.;

The water mud, stone warehouse, pulverized coal bunker, cement warehouse, warehouse, slag storage warehouse, etc.;

Water treatment: reservoirs, sewage pool, cans, sedimentation tank, deep well water treatment, drinking water network, etc.;

Made of paper: raw materials warehouse, towers, drum drying, chemical storage materials storage warehouse, etc.;

He: its quarry, food, pharmaceutical, environmental protection, shipbuilding and other industries.

Five, the main features:

1, no blind area, high precision;

2, two wire system technology, it is the differential pressure instruments, magnetostriction, rf admittance, magnetic flap instrument of substitute products;

3, shall be subjected to pressure, vacuum, temperature changes, inert gas, dust, steam and other environmental impact;

4, installation is simple, durable, free maintenance;

5, the output signal is 4 ma ~ 20 ma/HART protocol, calibration is simple, through digital LCD easy calibration operation, by setting up and programming software to realize simple configuration;

6, measurement sensitivity, fast refresh;

7, suitable for high temperature working condition, process temperature up to 200 ℃, when high temperature to extend the antenna is used up to 350 ℃.

Six, the technical parameters:

1, the working frequency: 6.8 GHz;

2, measuring range: cable type: 0-35 m pole type, coaxial type: 0-6 m;

3, repeatability, plus or minus 3 mm;

4, resolution: 1 mm;

5, sample: echo sampling/s 54 times;

6, the response speed: > 0.2 S (according to the specific use of the case may be);

7, precision: < 0.1%;

8, the output current signal: 4-20 ma;

9, communication interface: HART communication protocol;

10, process connection: G1-1/2, G3/4 flange: (, DN80, DN100, 6;

11, the process pressure: 1 ~ 60 bar;

12, power: 24 VDC ripple voltage (+ / - 10%) : 1 VPP;

13, power consumption: max22.5 mA;

14, environmental conditions: temperature: - 40 ℃ ~ + 250 ℃;

15, shell protection grade: IP68;

16, explosion-proof level: EXiaIICT6;

17, two wire connection: instrument power supply and signal output sharing two core cable;

18, cable entry: M20 x 1.5 (cable diameter 5 ~ 9 mm).

Seven, measurement considerations:

1, measurement range from the beam hitting a can of low starting point, but under special circumstances, if the tank is low for concave type or conical, when the level below this point cannot be measured.

2, if the medium to low dielectric constant when it is in low level, low visibility, at this time in order to ensure the accuracy of measurement, the recommendations will be zero at low altitude to the position of the C.

3, theory, measurement to achieve the position of the antenna tip is possible, but considering the corrosion and the influence of the adhesive, the final value of measuring range should be at least 100 mm distance from the tip of the antenna.

4, the overflow protection, additional on the blind spot can define a safe distance.

5, small measuring range related to the antenna.

6, with different concentration, foam can absorb microwaves, and it can be reflected, but under certain conditions can be measured.

7, measurement is beyond the scope of action when the measuring range beyond, instrument of 22 ma current output.

Eight, can debug through three ways:

1, by displaying the adjustment module PM;

2, through debugging software SOFT;

3, handheld programmer by HART.

Through the SOFT software debugging:

No matter the signal output, 4-20 ma/HART, radar sensors can be through the software debugging.Is instrument with the SOFT software debugging, need a meter CONNECTCAT drives.

Using software debugging, for the radar instrument 24 VDC power up, at the same time connect HART adapter front end with a resistance of 250 ohms.If the one-piece HART resistance (250 ohm internal resistance) of electricity meter, there is no need for additional external resistance, HART adapter can and 4...20 ma line in parallel.

Nine, installation guide:

The following installation instructions applicable to bar type probe and cable type, tubular type probe measurement has nothing to do with the installation.

1, the installation location:

A, distance of tank wall advice 1/6 - a quarter of the tank diameter (at least 300 mm, concrete tank at least 400 mm).

B, do not install in the middle of the metal cans;

C, don't put in the mouth;

D, when choosing the length of the probe, pay attention to the bottom of the probe from the tank bottom is about more than 30 mm;Pay attention to the medium temperature.

2, tank obstacles:

Pay attention to when installation probe at least 200 mm away from the obstacle.

3, remove interference:

, clutter echo suppression: a software which can realize the interference echo suppression, so as to achieve the ideal measurement effect;

B, the by-pass pipe and guided wave tube (only applicable to liquid) for viscosity don't play in the 500 CST, can adopt by-pass pipe, guided wave tube or pipe to avoid interference.

4, liquid standard installation:

For 500 CST or less and not easy to produce the adhesive medium viscosity, tubular probe is an ideal scheme, its characteristics are as follows:

A,, excellent reliability.

B, can be used in any medium, dielectric constant is greater than or equal to 1.4 measurement has nothing to do with the conductivity of medium;

C, tank obstacles and short tube size does not affect the measurement;

D, than bar type probe can withstand the lateral pressure is high;

E, for the high viscosity of the medium, it is recommended to use lever probe.

5, lie the tank and the installation of vertical tank:

A, tube type probe and lever type probe length more than 6 meters to 6 meters for measuring distance of tank, can choose 8 mm cable type probe;

B, installed and fixed mode with solid powder storehouse measurement;

C, to the distance away from the tank wall unlimited, as long as avoiding probe contact tank wall;

D, if the tank obstacles more or too close to the ground rod, please choose tube type probe.

6, corrosive medium measurement:

If the corrosive medium, can choose lever probe measure set of a plastic casing.

Ten, use notice:

1, the meter used in outdoor, install the awning or protect box, lest time grew, LCD aging by sunlight.If used in the corrosive gas environment, need to install anti-corrosion coat, and outer casing and tighten the instrument into the outlet terminals.Where corrosive gas or liquid is used, or at the beach, sea use, need to choose anti-corrosion type.

2, wire, cable protection tube, pay attention to the seal to prevent water, to prevent rodent bite by rats, etc.

3, instrument, although itself with lightning protection device, instrument when used in dore region, Suggestions on the instrument into the outlet end of the other special installation of lightning protection devices.

4, instrument used in special hot and cold place, namely the ambient temperature may exceed the instrument work requirements, proposed around the liquid level meter high resistance, low temperature device.

5, radar and measured the level of vertical, the launch of the cone in radar electromagnetic wave must be within the scope of other obstacles.

6, if the < - 20 ℃ or > + 60 ℃ temperature for use, please in advance the company's technical service department.

7, using the environment with dust, vapor, mist, liquid level bubble, floats, liquid mixing, waves, and so on and so forth, please our company in advance technical service department, need to discriminate.

Eleven, parameter table:

Table 1:

Product category

ZWRD801

ZWRD802

ZWRD803

Product pictures

6 intelligent radar level gauge (anti-corrosion type) 801. The PNG6 intelligent radar level gauge (flange anti-corrosion type 802. PNG6 intelligent radar level gauge (fixed flange) 803. The PNG

Range of application

Simple process conditions, corrosive liquid, paste, solid 
Such as: 
The water tank
Acid and alkali storage tank 
Slurry storage tank 
Solid particles
Small storage tanks

Storage container or process corrosive liquid, paste, solid 
Such as: 
The water tank
Acid and alkali storage tank 
Slurry storage tank 
Solid particles
Small storage tanks

To adapt to all kinds of storage container, liquid, paste, solid 
Such as: 
Crude oil, light oil tank
Raw coal, pulverized coal positions
Volatile liquid storage tanks
Coke material level 
Slurry storage tank 
Solid particles

measuring The amount van wai

20m

20m

30m

pass cheng evenPick up

G11/2or11/2NPTThe screw thread

The flange

The flange

pass cheng wenThe degree of

- 40-130℃

- 40-150℃

- 40-250℃

pass chengpressure force

-1.0-3bar

-1.0-20bar

-1.0-40bar

heavy after sex

± 3mm

± 3mm

± 3mm

fine The degree of

< 0.1%

< 0.1%

< 0.1%

frequency The rate of van wai

6.8GHz

6.8GHz

6.8GHz

explosion-proof/Protection grade

EXiaIICT6/IP68

EXiaIICT6/IP68

EXiaIICT6/IP68

The letter No.Lose, Out of the

4…20mA/HART(The two lines)

4…20mA/HARTTwo lines)

4…20mA/HART(The two lines)

Browse:
Return To The Top

分享到: