Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
Tel:0517-86918678
Fax:0517-86918679
Email:zhongweick@163.com
Post Encoding:211600
ZW-UQK series Top mounted float level controller Composed of a floating ball, rod etc.. The connecti…
Description:
Productoverview:
ZW-UQK seriesTop mounted float level controllerComposed of a floating ball, rod etc..The connecting flange is arranged in the container on the top of the floating ball by liquid volume equal according to the principle of floating on the surface, when the liquid level change container when the float with the next movement due to the magnetic effect, float level controller reed by magnetic attraction, the liquid level change into electric signal by using digital display instrument according to the actual position of the liquid, float level controller to achieve remote monitoring and control level.
Two, work principle:
ZW-UQK series <strong> top mounted float level controller</strong> is composed of a floating ball assembly and transformation of two parts.When the measured level changes, the floating ball will move up and down, to the end of the connecting rod magnet do the opposite direction.Reach level two control points, through the magnetic repulsion of the marine float level controller is the conversion mechanism of the magnetic steel quickly rejected to the other side, the micro switch is turned on or off, the switch signal output, to achieve the alarm or automatic control for marine float level controller.
Three, application:
ZW-UQK series <strong> top mounted float level controller</strong> is suitable for copper, aluminum, stainless steel and other materials that do not corrode the container control night.When the liquid level reaches high, lower limit position, the controller output electric shock switch signal, realize the liquid level alarm or pump power.It can be widely used in petroleum, chemical industry etc..
Four, main features:
1, advanced design and strict manufacturing process provides a reliable guarantee for product quality.
2, the shell is made of ABS, PP, PVC plastic, high strength, good corrosion resistance.
3, cable with special materials, oil resistant, acid, alkali, corrosion resistance is superior.
4, simple structure, reliable performance.Stable and reliable output on and off switch signal, no misoperation, high reliability.
5, simple installation, convenient debugging, on the mobile positioning block, can freely adjust the liquid level control range.
12, flameproof explosion-proof grade: Exd II BT4 II CT6 Exia intrinsically safe;
13, protection grade: IP65.
Six, installation instructions:
External installation:
1, the installation location should be away from the water inlet, otherwise the switch will malfunction caused by the fluctuation of water inlet.
2, if the float level switch device in the vessel wall, can be installed L type steel bracket.
3, if the switching device can be installed in the stirring area, wave tube or wave baffle.
4, the selection of pipe flange diameter greater than the diameter of the connecting pipe of the floating ball.
Recommend the use of multiple core cable wiring, 5.
6, controlled by the line load must match the float switch contact capacity.
7, the measured liquid proportion must be greater than the proportion of floating ball.
8, the floating ball movement has orders in the factory is adjusted according to the customer, please do not arbitrarily adjust the float position.
Internal wiring installation:
1, when the float switch used in motor, relay, solenoid coil circuit has an inductive load, in parallel across the load protection circuit such as: RC (buffer), rheostat, diode etc..
Note: please do not float switches are directly connected to the electromagnetic valve, motor or solenoid switch.
2, when the floating ball switch is used in capacitors, hot bulb, long cable and capacitive load, will produce a surge current in the switch contacts; in the float switch is connected in parallel with the protection circuit, such as current limiting resistors or surge absorber etc..
Seven, wiring and contact instructions:
1, open the box, the cable from the inlet through, and lock line inlet cable fixed head, according to the nameplate and wiring board terminal station logo on the terminal of the contact line on the corresponding access.
From the 2 wiring board, digital identification terminal table corresponding to a contact from top to bottom of the floating ball.
3, float ball joint is divided into three forms:
1A said: when the liquid level is higher than the floating ball contact A-C;
The 1B said: when the level is below the floating ball contact B-C;
The 1AB said: when the A-C level is below the floating ball contact open, B-C connected; the liquid level is higher than the floating ball when the A-C contact is connected, disconnect the B-C.
4, please tighten the lid after the completion of the connection and the connecting port is fixed, in order to ensure the waterproof junction box.
Eight, matters needing attention:
1, regular cleaning of debris and dirt rod and the floating ball (depending on the water quality and cycle);
2, regular inspection of all parts are firmly;
3, should consider the proportion of liquid, in order to ensure the smooth float to float;
4, the control circuit load does not overload use (less than the capacity of contact use);
5, electrical wiring box interface must be down;
Please choose anti-corrosion type 6, alkali liquid;
7, the floating ball and the connecting rod is connected with the container tube shall not touch the process.
Nine, common faults and exclusion:
1, failure analysis and troubleshooting of floating ball movement
The liquid proportion is less than the proportion of floating ball to re confirm the proportion of floating ball;
The floating ball, and the Water Leakage company to replace the floating ball;
The floating ball to remove foreign bodies stuck in foreign body.
2, the floating ball moves, but no signal output
The float position offset, adjust the float position;
The magnetic reed switch is damaged, replace the magnetic reed switch.
3, the output signal is not normal, to eliminate the magnetic field near the magnetic field interference;
4, maintain the signal, unable to recover, the floating ball can not return, a foreign body stuck to remove foreign bodies;
5, there will be a two signal output, ring position, adjusting ring buckle position.
Ten, specification data sheet:
Model name
explosion-proof
Grade
Medium pressure
(MPa)
Medium temperature
(c)
Switching difference
(Mm)
Setting
mode
install
form
Power & contact
Capacity and life
ZW-UQK-01type
One
One hundred and fifty
Less than 14
Not adjustable
level
Communication:
220V,1.5A,
110V,2.5A
Direct:24V
,2.5A,240V,
0.5A
Life:Five*TenTwo
ZW-UQK-01--dIIBT4type
DIIBT4
Four
ZW-UQK-02type
One
One hundred and fifty
25~250
Level adjustable
level
ZW-UQK-02-dIIBT4type
DIIBT4
Four
ZW-UQK-03type
One
One hundred and fifty
8~1000
Stepless adjustable
vertical
ZW-UQK-03-Diibt4type
DIIBT4
Four
Eleven, the selection of encoding:
Specification code
Name
ZW-UQK
Ordinary type float level controller (Zhongwei control)
ZW-UQKS
With a self-test type float level controller
form
Control range
Adjust the way
The installation form
basic form
-01
10mm
Not adjustable
Side mounted
-01N
60mm
Not adjustable
Side mounted
-01T
40mm
Adjustable
Top mounted
-02
25-550mm
Level adjustable
Side mounted
-03
8-2000mm
Stepless adjustable
Top mounted
-04
10mm
Not adjustable
The outer level
-
Fifty
Flange diameter DN50 or 2
Eighty
Flange diameter Mao 80 or 3
One hundred
Flange diameter DN100 or 4
Explosion-proof options
O
Ordinary type
D
Flameproof
E
Intrinsically safe
working temperature
S
Standard type
M
Medium temperature
H
High temperature type
-.
Medium density g/cm3
-.
The working pressure of MPa
Note: Please specify the specific process of connection, the size and position of action point.
12, design selection and ordering information:
1, the liquid level switch device specifications;
2, measuring range;
3, working pressure and temperature;
4, material control device;
5, the special requirements of negotiation;
6, whether the liquid level device supporting the supply vessel flange, bolts, nuts, washers and valve sealing parts, so that the correct selection.
Customer service service commitment:
1, our level switch series products quality problems within twelve months, responsible for free maintenance.
2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.