WRN series Thermal sleeve type thermocouple The heat protection casing and thermocouple separation c…
Description:
Productoverview: WRN seriesThermal sleeve type thermocoupleThe heat protection casing and thermocouple separation combination, the use of the user can be nested in thermal protection tube welding equipment or pipeline, and then loaded thermocouple can be used, has the advantages of improving the protection of pipe work pressure and service life, and convenient maintenance and replacement in the thermocouple, the factory production of heat set the protective tube and deep blind hole processing technology, the protection of the end of the pipe without welding, thereby improving heat protection tube strength and service life. Two, work principle: WRN seriesThermal sleeve type thermocoupleTwo different components of the conductor (called thermocouple wire or thermal electrode) is connected to the two ends of the synthetic circuit, when the junction temperature at the same time, in the loop will produce electromotive force, this phenomenon is called the thermoelectric effect, and this is called thermal electromotive force emf.A thermocouple is used to measure temperature of this principle, which is directly used for measuring the temperature of a medium called the working end (also known as the measuring end), the other end is called the cold end (also known as the end of the cold end compensation); and display instrument or meter display instrument connection, will point out that the thermoelectric potential generated by thermocouple. Three, application: WRN seriesThermal sleeve type thermocoupleSuitable for steam pipe, boiler and other on temperature, pressure and flow requirements of the place.
Fourth, the main features: 1, simple assembly, convenient replacement; 2, a spring type temperature sensing element, good anti vibration performance; 3, a large range of temperature; 4, high mechanical strength, good pressure resistance.
Five, technical parameters: 1, electrical outlet: M20x1.5, NPT1/2; 2, size: M20x1.5, NPT1/2 connection; 3, protection grade: IP65. Six, thermal sleeve type protective sleeve installation steps are as follows: 1, in the pipeline of the measured medium hole.In order to protect the triangle cone casing firmly installed on the pipe wall, the through holes can drill a diameter of 38mm, and then expanded to 42mm in diameter, 38mm diameter hole reaming will keep 10mm long. 2, the installation of welding casing.Install the casing length, should ensure the protection of the triangle cone sleeve firmly against the hole diameter of 38mm. 3, inserted into the protective sleeve.When the triangular cone protective sleeve with 38mm hole seal, protect casing and casing should be installed between the welding gap enough. 4, the protective sleeve is welded on the installation sleeve.
7, so that ordinary thermal sleeve type thermocouple: 1, the product structure
TwoParameter
namecall
typeNumber
Graduation
Measuring range
Nominal pressure
flowspeed
Protection tube material
Single thermocouple
WRNR-01
K
0~600C
Less than 29.4MPa
Less than 100m/s
1Cr18Ni9Ti
WRER-01
E
Twin thermocouple
WRNR2-01
K
WRER2-01
E
Eight,The flue duct, the thermocouple: 1, use commonly used in temperature measurement and flue duct. 2, the product structure
ThreeParameter
namecall
typeNumber
Graduation
Measuring range
Nominal pressure
Protection tube material
Single thermocouple
WRNR-12
K
0~800C
Less than 9.8MPa
1Cr18Ni9Ti
WRER-12
E
Twin thermocouple
WRNR2-12
K
WRER2-12
E
A single heat resistance
WZP-12
Pt100
-200~500C
Double heat resistance
WZP2-12
Nine, high temperature and high pressure that: 1, use: is suitable for high temperature and high pressure or high pressure. 2, the product structure
ThreeParameter
namecall
typeNumber
Graduation
Measuring range
flowspeed
Protection tube material
Single thermocouple
WRNR-13
K
0~800C
Less than 100m/s
0Cr18Ni12M02Ti
WRER-13
E
Twin thermocouple
WRNR2-13
K
WRER2-13
E
A single heat resistance
WZP-13
Pt100
-200~500C
Double heat resistance
WZP2-13
The length of product placementL (mm):50100150 Ten, medium temperature and medium pressure: 1, the product structure
TwoParameter
namecall
typeNumber
Graduation
Measuring range
Nominal pressure
flowspeed
Protection tube material
Single thermocouple
WRNR-14
K
0~800C
Less than 29.4MPa
Less than 100m/s
1Cr18Ni9Ti
WRER-14
E
Twin thermocouple
WRNR2-14
K
WRER2-14
E
A single heat resistance
WZP-14
Pt100
-200~500C
Double heat resistance
WZP2-14
immersion on lengthL (mm):50100150200250300 350400450500
11, the low temperature and low pressure:
1, the product structure
TwoParameter
namecall
typeNumber
Graduation
Measuring range
Nominal pressure
flowspeed
Protection tube material
Single thermocouple
WRNR-15
K
0~800C
Less than 2MPa
Less than 9m/s
The protective tube (III) M33*2
WRER-15
E
Twin thermocouple
WRNR2-15
K
WRER2-15
E
Single thermocouple
WRNR-15A
K
The protective tube (IV) ZG1 "(NPT1 ")
WRER-15A
E
Twin thermocouple
WRNR2-15A
K
WRER2-15A
E
A single heat resistance
WZP-15
Pt100
-200~500C
M33*2
Double heat resistance
WZP2-15
A single heat resistance
WZP-15A
ZG1 "(NPT1 ")
Double heat resistance
WZP2-15A
Protection tube material:1Cr18Ni9Ti immersion on lengthL (mm):50100150200250300 350400450500
Twelve, flange connection description: 1, the product structure
TwoParameter
namecall
typeNumber
Graduation
Measuring range
Nominal pressure
flowspeed
Protection tube material
Single thermocouple
WRN-4318
K
0~800C
4MPa
Less than 80m/s
1Cr18Ni9Ti
WRE-4318
E
0~600C
Twin thermocouple
WRN2-4318
K
0~800C
WRE2-4318
E
0~600C
A single heat resistance
WZP-4318
Pt100
-200~500C
Double heat resistance
WZP2-4318
immersion on lengthL (mm):50100150200250300 350400450500
Thirteen, the conical pipe flange connection: 1, the product structure
Two,parameter
namecall
typeNumber
Graduation
Measuring range
Nominal pressure
flowspeed
Protection tube material
Single thermocouple
WRN-43C
K
0~800C
4MPa
Less than 80m/s
1Cr18Ni9Ti
WRE-43C
E
0~600C
Twin thermocouple
WRN2-43C
K
0~800C
WRE2-43C
E
0~600C
A single heat resistance
WZP-43C
Pt100
-200~500C
Double heat resistance
WZP2-43C
immersion on lengthL (mm):50100150200250
Fourteen, selection list:
W
R
Specifications
Content (Zhongwei control)
R
30- platinum rhodium 6
P
10- platinum rhodium
N
Nickel chromium nickel silicon
E
Nickel - chromium (chromium Constantan)
Thermocouple material
-
One
No fixed device
Two
Fixed screw type
Three
Movable flange
Four
Fixed flange
Five
A movable flange square form
Six
Fixed thread taper protection tube
Fixed form
Two
Splash proof
Three
Waterproof type
Four
Flameproof type
Connection box
Zero
16mm protection tube
One
25mm protection tube (double casing)
Two
16mm high aluminum tube (single tube)
Three
20mm high aluminum tube
DesIgn Serial Number
.
W
R
.
-
.
.
.
.
Example: thermocouple, type K, class I, fixed thread M27 * 2, protective tube 316L, length 450mm, the insertion depth of 300mm.WRN-220, K I, L * l=450 * 300, grade I, protective tube 316L, thread M27 * 2. Note: 1, grade I, grade a thermocouple thermal resistance according to the ordering protocol; 2, the protective tube is made of 1Cr18Ni9Ti material, the order according to the agreement; 3, 12 types of connection thread is M60X3, 12A connection thread is NPT2".The protective tube is made of 1Cr18Ni9Ti. Eight, design selection and ordering information: Please provide the indexing number, precision grade, fixed form, protection material, length or depth of insertion tube (protective tube length L=l+150, special insertion depth and protection tube material can be ordered according to the agreement). Customer service service commitment: 1, my company sold Zhongwei thermocouple series product quality problems within twelve months, responsible for free maintenance. 2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement. 3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost. 4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost. 5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.