Low smoke zero halogen flame retardant control cable

低煙無鹵阻燃控制電纜.jpg
  • 低煙無鹵阻燃控制電纜.jpg
Low smoke zero halogen flame retardant control cable is suitable for ac 50 to 60 hz, rated voltage 7…

Description:

An overview, cables:
Low smoke zero halogen flame retardant control cable is suitable for ac 50 to 60 hz, rated voltage 750 v and below, low smoke, halogen-free, non-toxic, non-corrosive, non-pollution cable) flame retardant requirements used as control monitoring circuit, etc.
Second, the production of standard:
Low smoke zero halogen flame retardant control cable to the enterprise standard and reference to GB9330-88 this product is suitable for use in ac 50 to 60 hz, rated voltage 750 v and below, low smoke, halogen-free, non-toxic, non-corrosive, non-pollution cable) flame retardant requirements used as control monitoring circuit, etc.
Three control cables, low smoke zero halogen flame retardant technology performance:
The product reference articles IEC227, IEC1034, IEC332 international standard design
Four control cables, low smoke zero halogen flame retardant performance requirements:
1, into A bundle of burning A or B, (coking section height) : 2.5 m or less.
The distance of 2, secondary (without burning) : 50 mm or higher;
3, smoke degree (minimum light transmittance) 60% or higher;
4, HCL content acuities were 0.5 mg/g.
Five, the model name:

model

The name of the cable

KVV

Copper low smoke zero halogen polyolefin insulated and sheathed flame-retardant control cable

KVVP

Copper low smoke zero halogen polyolefin insulated and sheathed woven block flame-retardant control cable

KVVP2

Copper low smoke zero halogen polyolefin insulated and sheathed copper tape screened flame-retardant control cable

KVV22

Copper low smoke zero halogen polyolefin insulation and sheath steel tape armoured flame-retardant control cable

KVVR

Copper low smoke zero halogen polyolefin insulated and sheathed flame-retardant control cable

KVVRP

Copper low smoke zero halogen polyolefin insulated and sheathed textile block flame-retardant control cable

KVVP2-22

Copper low smoke zero halogen polyolefin insulated and sheathed copper belt BingBiGang belt sheathed flame-retardant control cable

KYJY

Copper core with cross-linked polyethylene insulation polyolefin sheath low smoke zero halogen flame retardant control cable

KYJYP

Cross-linked polyethylene insulating tape armored low smoke zero halogen (B or C) A kind of flame retardant power cable

KYJYP2

Communication polyethylene insulated fine steel wire armoured low smoke zero halogen (B or C) A kind of flame retardant power cable

KYJYP3

Copper core with cross-linked polyethylene insulation polyolefin sheath aluminum-plastic composite belt shielding low smoke zero halogen flame retardant control cable

KYJY23

Copper core with cross-linked polyethylene insulation polyolefin sheath steel tape armoured low smoke zero halogen flame retardant control cable

KYJYP2/23

Copper core with cross-linked polyethylene insulation polyolefin sheath copper tape BingBiGang tape armored low smoke zero halogen flame retardant control cable

KYJYP3/23

Copper core with cross-linked polyethylene insulation polyolefin sheath with lu: su composite BingBiGang armoring low smoke zero halogen flame retardant control cable

"WDZ" : it means low smoke zero halogen flame retardant
Six, cable specifications:

model

Conductor nominal section (was)

0.5

0.75

1.0

1.5

2.5

4

6

10

some

KVV
KVVP

-

2 ~ 61

2 ~ 14

2 ~ 10

KVV2

-

4-61

4 ~ 14

4 ~ 10

KVV22 
KVVP2-22

-

7 ~ 61

4-61

4 ~ 14

4 ~ 10

KVVR

-

4-61

-

-

KVVRP

-

4-61

4 ~ 48

-

-

Note: recommend some series for: 2, 3, 4, 5, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 44, 48 and 52 and 61 core.
Seven, delivery requirements:
1, into a circle of 100 m, a dish should be greater than 100 m;
2, according to the supply and demand both sides agreement to allow any length of delivery, the length of the measurement error of plus or minus 0.5%.